DellEMC VNX1 Service Manual
DellEMC VNX1 Service Manual
VNX5100, VNX5300, VNX5500, VNX5700
| Port | IP | Username/Password |
|---|---|---|
| Management | 1.1.1.1-2/255.255.255.0 | admin/password |
| Maintenance | 128.221.1.250-251/255.255.255.248 | admin/password |
Engineering mode: press Ctrl+Shift+F12 and the type the password messner.
Drive Replacement
During hot swap to replace a hard disk, after remove the bad hard disk, wait one minute until the state is removed, and then insert a new hard disk, the state will be rebuilding.
When a hard disk is faulty, the Pool/LUN state changes to faulty. After the hard disk is rebuilt, the state will change to online.
-
For
Removed/Faultedstate. The fault light will be illuminated, it can be replaced by hot swap physically. -
For
Probationstate. The fault light will not be illuminated, and can not do Copy to Hotspare, so replace it by hot swap physically.
The Bus 1 Enclosure 1 Disk 11 show Probation state, and Copy to Hotspare failed.
The pool/lun show faulted.

SP event show the disk power down and removed.


-
For others state. Must to do Copy to Hotspare, wait drive state change to
Faulted, and then replace it by hot swap physically.
Storage Processor Replacement
・ VNX_5300_Procedures-Replacing_the_Storage_Processor_(SP)_in_DPE.pdf |