IBM System Storage DS3-5K Service Manual
IBM System Storage DS3-5K Service Manual
DS3500,3512
DS5020
Checking the LEDs
・ DS3500 Installation, User's, and Maintenance Guide.pdf?Checking the LEDs |


Drive activity LED (green)
Each drive has an activity LED. When this green LED is flashing, it indicates drive activity.
Drive status LED (amber)
Each drive has a status LED. When this amber LED is lit continuously, it indicates a drive failure.
When it is flashing, it indicates that the controller is identifying or building a drive.
Drive Replacement
DS3500,3512 - Storage Manager v10.10 or latest
Replace Drives option
- Wait the controller reconstructs parity of all the logical drives in that array, and hot spare drive is in-use state.
- Select the missing or failed drive and the in-use hot spare drive. Failed disk drive replacement
- Unplug the missing or failed drive, wait 60s then insert the new drive.
- Set the new drive as an hot spare.
Fail Drive option
- Unassign all hotspare drives first. This will prevent hotspare reconstruct and copyback operations.
- Fail drive. Recovery - Fail drive
- Unplug the missing or failed drive, wait 60s then insert the new drive.
- Reassign all hotspare drives.
DS5020
Confirm the drive in failed or offline state. Replacing hot-swap E-DDMs |
Battery Replacement
DS3500,3512
- Change logical drive to good controller. Change Ownership/Preferred Path
- Place bad battery of controller to offline. Recovery - Place controller
- Replacing a bad battery. Replacing a battery
- If necessary, place the controller to online. Recovery - Place controller
DS5020
- When the controller battery fails, first check the status of the battery LED. Battery unit LEDs |
- Make sure the "Service Action Allowed" and the "Service Action Required" LED are both illuminated, hot-swapping for replacement is permitted. Replacing a battery unit |
Powering off/on the storage subsystem
DS3500,3512
・ Turning off the storage subsystem |
・ Turning on the storage subsystem |
DS5020
・ Powering off the storage subsystem |
・ Powering on the storage subsystem |