Hitachi NAS Platform Service Manual

server CLI: manager/nasadmin
SMU: admin/nasadmin

Docs

Hitachi NAS Platform System Access Administration Guide 12.3.pdf |
NAS_Platform_v14_3_File_Service_Administration_Guide_MK-92HNAS006-26.pdf |
NAS_Platform_v14_3_Storage_Subsystem_Administration_Guide_MK-92HNAS012-25.pdf |

Battery Replacement

HNAS Battery Safety Manual.pdf |
Hitachi NAS Platform and Hitachi Unified Storage Series 4000 Hardware Reference 13.4.pdf?Replacing the NVRAM backup battery pack |

After the replacement is completed, wait for five minutes for the battery to initialize.

HNAS-4060:$ ver
HNAS-4060:$ new-battery-fitted --field --confirm
HNAS-4060:$ batt-log-show
...
2025-04-17 14:17:21+08:00 Battery exceeded life expectancy: 749 days since fitted, life expectancy is 730 days
2025-04-18 05:13:23+08:00 Voltage 7.77V, Current -0.01A, glue reg: 0xc1
2025-04-18 06:14:23+08:00 Voltage 7.76V, Current -0.01A, glue reg: 0xc1
2025-04-18 06:47:56+08:00 **** Battery not fitted! ****
2025-04-18 06:48:40+08:00 **** Battery is fitted ****
2025-04-18 06:48:40+08:00 Battery was disabled but has now been enabled
2025-04-18 06:52:05+08:00 **** Battery monitor starting release 11.2.3319.16 ****
2025-04-18 06:52:05+08:00 **** Battery is fitted ****
2025-04-18 06:52:06+08:00 MCP card id is 2 and revision is 10
2025-04-18 06:52:06+08:00 State changed to: Initializing
2025-04-18 06:52:06+08:00 Voltage 7.86V, Current -0.01A, glue reg: 0xc1
2025-04-18 06:52:07+08:00 Detected new battery, so need to set fitted date and initiate a conditioning cycle
2025-04-18 06:52:07+08:00 State changed to: Conditioning-1
2025-04-18 06:52:07+08:00 Voltage 7.86V, Current -0.01A, glue reg: 0xc1
2025-04-18 06:52:07+08:00 Conditioning cycle 1 start
HNAS-4060:$
HNAS-4060:$ batt-show
Battery is fitted, Conditioning 1 Discharging, 7.16V, 2.07A
Fault state: 0x4 (fault)
HNAS-4060:$
HNAS-4060:$ status
Power supply status:
Unit 1: OK
Unit 2: OK

Chassis battery status:
Unit 1: Fault

Board temperature:
MMB CPU Core 0 sensor: OK (26 C)
MMB CPU Core 1 sensor: OK (34 C)
MMB CPU Core 2 sensor: OK (29 C)
MMB CPU Core 3 sensor: OK (28 C)
MFB Inlet sensor: OK (30 C)
MFB Outlet sensor: OK (27 C)
MSM Board sensor: OK (29 C)

Fan status:
Chassis fan 1: Fitted Speed: OK (3100 rpm)
Chassis fan 2: Fitted Speed: OK (3100 rpm)
PSU1 fan: Fitted Speed: OK (13200 rpm)
PSU2 fan: Fitted Speed: OK (13600 rpm)

Chassis disk status:
md0: OK 5% full.
md1: OK 4% full.
md2: OK 0% full.
md3: OK 3% full.

Ethernet Aggregations:
ag1: Up

FC Links:
FC 1: Up
FC 2: Up
FC 3: Up
FC 4: Up

Server uptime: 366 days, 1 hour, 57 minutes, 56 seconds
Server date/time: 2025-04-18 07:03:05+08:00
HNAS-4060:$