HPE ProLiant DL580 Gen9 Service Manual
HPE ProLiant DL580 Gen9 Service Manual
Model - 846160-B21 - HPE DL580 Gen9
OEM - H3C UIS R690 G2
・ HPE ProLiant DL580 Gen9 Server Maintenance and Service Guide.pdf |
・ HPE_psg000134aen_us_HPE ProLiant DL580 Gen9 Server - Parts Support Guide.pdf |
・ HPE_c04444029_HPE ProLiant Gen 9 Troubleshooting Guide, Volume I_ Troubleshooting.pdf |
Firmware Upgrade
・ Online ROM Flash Component for VMware ESXi - HPE Integrated Lights-Out 4.pdf |
・ System ROM Flash Binary - HPE ProLiant DL580 Gen9 (U17).pdf |
・ HPE Gen9 Server Upgrade BIOS Firmware on iLO4.pdf |
Troubleshooting
CASE: Flash red light four times per second of Health LED
服务器前部 Health LED 每秒闪 4 次红灯,按开机键无反应,登录 iLO 检查,未查到具体报错信息。
・ Front panel LEDs and buttons
Health LED:
• Solid green = Normal
• Flashing amber = System degraded
• Flashing red (1 Hz/cycle per sec) = System critical
• Fast-flashing red (4 Hz/cycles per sec) = System power fault


初步判断为电源背板套件故障,或线缆接触不良。
CASE: CPU - Uncorectable Machine Check Exception
CPU MCE (Board 0, Processor 1, APIC ID Ox0000002A, Bank Ox00000001, Status OxBF80000000100134, Address0v000000100EEAA040.Micc0v0000000000000086)

The current server System ROM: U17 v2.20(05/1612016) may cause this error. Upgrade the System ROM to eliminate the error.
・ An Increased Rate of Uncorrectable Machine Check or Uncorrectable Memory Errors May Occur on Servers Configured with Intel Xeon E7-4800 v3 or E7-8800 v3-Series Processors and System ROM Version 2.20.pdf |
・ https://support.hpe.com/connect/s/softwaredetails?language=en_US&collectionId=MTX-07347f7a083340a0&tab=Fixes&softwareId=MTX_dec96ac5f1f144d4815f67306b
CASE: No raid controllers detected
服务器内存故障,关机断电更换内存后,开机识别不到阵列卡,属实莫名奇妙,拔插阵列卡也不好使。历经多次断电重启,最后又莫名奇妙好了,有点服了。
猜测是阵列卡电池有问题?
先记录一下,后续遇到相同问题再研究看看。
还有一次是服务器识别不到(偶尔能识别,重启后又丢失)阵列卡 Smart Array P830i Controller。经过排查,在 BIOS 中重新配置 boot mode = legacy,raid mode = disabled 解决,即禁用软 RAID。