HPE ProLiant DL580 Gen9 Service Manual

Model - 846160-B21 - HPE DL580 Gen9
OEM - H3C UIS R690 G2

HPE ProLiant DL580 Gen9 Server Maintenance and Service Guide.pdf |
HPE_psg000134aen_us_HPE ProLiant DL580 Gen9 Server - Parts Support Guide.pdf |
HPE_c04444029_HPE ProLiant Gen 9 Troubleshooting Guide, Volume I_ Troubleshooting.pdf |

Firmware Upgrade

Online ROM Flash Component for VMware ESXi - HPE Integrated Lights-Out 4.pdf |
System ROM Flash Binary - HPE ProLiant DL580 Gen9 (U17).pdf |
HPE Gen9 Server Upgrade BIOS Firmware on iLO4.pdf |

Troubleshooting

CASE: Flash red light four times per second of Health LED

服务器前部 Health LED 每秒闪 4 次红灯,按开机键无反应,登录 iLO 检查,未查到具体报错信息。

Front panel LEDs and buttons

Health LED:

• Solid green = Normal
• Flashing amber = System degraded
• Flashing red (1 Hz/cycle per sec) = System critical
• Fast-flashing red (4 Hz/cycles per sec) = System power fault


初步判断为电源背板套件故障,或线缆接触不良。

CASE: CPU - Uncorectable Machine Check Exception

CPU MCE (Board 0, Processor 1, APIC ID Ox0000002A, Bank Ox00000001, Status OxBF80000000100134, Address0v000000100EEAA040.Micc0v0000000000000086)

The current server System ROM: U17 v2.20(05/1612016) may cause this error. Upgrade the System ROM to eliminate the error.

An Increased Rate of Uncorrectable Machine Check or Uncorrectable Memory Errors May Occur on Servers Configured with Intel Xeon E7-4800 v3 or E7-8800 v3-Series Processors and System ROM Version 2.20.pdf |
https://support.hpe.com/connect/s/softwaredetails?language=en_US&collectionId=MTX-07347f7a083340a0&tab=Fixes&softwareId=MTX_dec96ac5f1f144d4815f67306b

CASE: No raid controllers detected

服务器内存故障,关机断电更换内存后,开机识别不到阵列卡,属实莫名奇妙,拔插阵列卡也不好使。历经多次断电重启,最后又莫名奇妙好了,有点服了。
猜测是阵列卡电池有问题?
先记录一下,后续遇到相同问题再研究看看。

还有一次是服务器识别不到(偶尔能识别,重启后又丢失)阵列卡 Smart Array P830i Controller。经过排查,在 BIOS 中重新配置 boot mode = legacyraid mode = disabled 解决,即禁用软 RAID。