IBM Storwize V7000 Gen1,2 Service Manual
IBM Storwize V7000 Gen1,2 Service Manual
IBM Storwize V7000 Gen1,2
| Canister and port | IPv4 address | IPV4 subnet mask | User/Password |
|---|---|---|---|
| Canister 1 (left) port 1 (left) | 192.168.70.121 | 255.255.255.0 | superuser/passw0rd |
| Canister 2 (right) port 1 (left) | 192.168.70.122 | 255.255.255.0 | superuser/passw0rd |
Hard Drive Replacement
Hard Drive LEDs
・ Drive indicators for control enclosures |
Run Fix Procedures
磁盘显示脱机

显示无从属卷

查看事件信息

运行修订步骤

核对坏件信息,下一步

选择【继续更换驱动器】,下一步

更换驱动器后,下一步


修订步骤完成,关闭

驱动器恢复正常

有时候点击下一步后,界面会无反应,其实后台正在运行,请耐心等待,不要重复点击。
Cleanup the ghost offline drive
There seems to be a bug in 6.2 and 6.3 of IBM's V7000 code that when replacing a bad drive, the V7000 is not properly deleting the bad drive information from the system.
The end result is that you have a drive that shows up in the list,but you cannot do anything to it in the GUI.
Login through the CLI, executing the following command:
svctask chdrive -use failed <drive-id> |
The GUI will need refreshed to reflect the changes properly. You may need to log out then back in.
Troubleshooting
CASE: 阵列 MDisk 不一致

Data Integrity Issue when Drive Detects Unreadable Data
Reference
・ IBM Storwize V7000 Troubleshooting, Recovery, and Maintenance Guide.pdf |