PERC 9 controllers import foreign configuration fails with configuration conflict after replacement

PERC H730p
R740

SYMPTOMS

When importing the preview foreign configuration, a configuration conflict is displayed and the imported are invalid argument.

CAUSE

The hard drive's configuration is inconsistent with PERC controller current configuration.

SOLUTION

  1. Poweroff, remove all hard drives, enter the perc controller and clear the configuration.
  2. Poweroff, insert all hard drives, enter the perc controller and check the array information(the foreign config will import automatic).