IBM XIV Storage System Service Manual
IBM XIV Storage System Service Manual
2812-A14 7803483
technician/teChn1cian
admin/adminadmin
Both XCLI and IBM XIV Storage Management GUI management is run over TCP port 7778.
Module


Module USB-to-serial connections

- USB-1 port in module 1 connects to Serial port in Module 3.
- USB-1 port in module 2 connects to Serial port in Module 1.
- USB-1 port in module 3 connects to Serial port in Module 2.
And so on for each group of 3 modules.
1-3, 4-6, 7-9, 10-12, 13-15

- USB-2 port in module 5 connects to Swtich 1 (Lower switch).
- USB-2 port in module 6 connects to Swtich 2 (Upper switch).
- USB-2 port in module 1 connects to UPS 1 (Lower UPS).
- USB-2 port in module 2 connects to UPS 2 (Middle UPS).
- USB-2 port in module 3 connects to UPS 3 (Upper UPS).
- USB-2 port in module 4 connects to ATS.
Shutdown & Startup
Shudown:
- System > System Settings > Shutdown System.
- Waitting all leds are off.
- Turn off all 3 output circuit breakers on all 3 UPSes.
- Power off all 3 UPSes.
- Unplug left side battery on all 3 UPSes.
- Turn off all 4 output circuit breakes on ATS.
Startup:
- Check ATS power source input led is ok.
- Plug left side battery on all 3 UPSes.
- Turn on all 4 output circuit breakes on ATS, check output led is ok.
- Turn on all 3 output circuit breakers on all 3 UPSes.
- Press the 3 "Test" buttons simultaneously on all 3 UPSes.
- Waitting system startup.
XCLI
> C:\xcli -c my_system -u technician -p technician event_list |
Referenece